Cisco N540X-4Z14G2Q-D Router

Cisco N540X-4Z14G2Q-D Router

Condition: New in Box
Stock Status:Orderable
Product Code: N540X-4Z14G2Q-D
  • Global Price List Information (GPL)

  • Category:
    Subcategory:
  • Model: N540X-4Z14G2Q-D
  • Description:
  • Price: USD
    Last Update:
  • End-of-Sale and End-of-Life Information (EOL/EOS)

  • Release Date:
  • End-of-Sale Date:
  • End-of-Support Date:
2026-03-06 :Updated

The Cisco Network Convergence System (NCS) 540 Small Density Routers represent a significant advancement in sub-100G routing technology, specifically engineered to meet the growing demands of modern communication service providers. As network traffic surges due to bandwidth-intensive applications like 5G, AR/VR, and the Internet of Things (IoT), these platforms provide a robust, carrier-class solution for Radio Access Network (RAN) backhaul and mission-critical enterprise environments.

By integrating the powerful IOS XR operating system into a compact, temperature-hardened form factor, these routers facilitate the "IP-fication" of mobile and wireline networks. They are designed to support a unified, end-to-end architecture that simplifies cross-domain orchestration while ensuring high reliability and low latency for next-generation multimedia and machine-to-machine communication.

Product overview

The NCS 540 Small Density series consists of several variants, including the N540X-6Z18G-SYS-A/D, N540X-8Z16G-SYS-A/D, N540X-4Z14G2Q-A/D, N540-6Z14S-SYS-D, N540-6Z18G-SYS-A/D, N540X-6Z6G-SYS, and N540-8Z12G-SYS-D. These platforms are built to be highly versatile, featuring native 25G interfaces and a programmable Segment Routing (SR) fabric. Their design prioritizes energy efficiency and physical durability, with options for both fanless, passively cooled units and active-fan models that comply with strict ETSI and GR-3108 standards for indoor and outdoor deployment.

These routers are optimized for diverse use cases ranging from 5G cell sites and Fixed-Wireless Access (FWA) to FTTx and utility networks. By leveraging Cisco’s Crosswork automation suite, the series supports secure zero-touch provisioning and advanced telemetry, allowing operators to deploy services flexibly and maintain high security through features like secure boot and runtime defense.

Features and benefits

  • Advanced Connectivity: Industry-leading native 25G interfaces in a sub-100G bandwidth form factor, supporting a wide range of Ethernet options (10/100/1000M, 1/10/25G).
  • High-Precision Timing: Full compliance with G.8273.2 Class C timing requirements, essential for 5G NR synchronization.
  • Robust Security: Includes Trust Anchor infrastructure, secure boot, image signing, and comprehensive runtime defense mechanisms.
  • Flexible Deployment: Available in 1 RU and 2.5 RU form factors with both passively cooled (fanless) and fan-assisted options, suitable for harsh outdoor cabinets and indoor environments.
  • Automation and Programmability: Supports Segment Routing (SR-MPLS and SRv6) and EVPN, with full integration for model-driven telemetry and NC/YANG-based service exposure.
  • Energy Efficiency: Ultra-low power consumption, with typical usage below 70W and a maximum of 100W.
  • Operational Reliability: Conformal-coated, I-Temp compliant hardware designed to withstand extreme temperature ranges and environmental conditions.
  • Simplified Management: Fully compatible with the Cisco Crosswork automation suite for zero-touch provisioning and streamlined network lifecycle management.
2026-03-06 :Updated

Product overview

The next phase of the network traffic explosion will be driven by use cases that make massive demands on communication service providers. Not only do these new-age applications stipulate greater data bandwidth, but they also need to be complemented by ultra-reliable, low-latency communications to deliver use cases like AR/VR media, UltraHD and new multimedia consumer experiences, massive Internet of Things (IoT), tactile internet, smart cities, AI surveillance, smart health, and Machine-to-Machine (M2M) applications such as smart meters.

Cisco Network Convergence System 540 (NCS 540) Small Density Routers, part of the larger NCS 540 router family, are designed for cost-effective delivery of next-generation services and applications for mobile and wireline. These routers are sub-100G-bandwidth, cost-effective, native-25G, carrier-class, I-Temp, conformal-coated, ETSI-compliant, ultra-low-power, devices capable of Class-C timing, best-in-class security, service exposure using NC/YANG, streaming telemetry, and flexible rollouts using SDN. Built for deployment in any-gen RAN backhaul, sub-6 5G cell sites, Fixed-Wireless Access (FWA), small-cell backhaul, FTTx, utilities, mission-critical enterprise applications, and low-speed Ethernet rings, the three variants of NCS 540 Small Density Routers support a programmable SR (Segment Routing) fabric and EVPN (Ethernet Virtual Private Network) as overlay for a unified end-to-end architecture with cross-domain orchestration via the industry-leading IOS XR software bundled with best-in-class services.

Key product highlights

●     Cell site routers based on IOS XR extending Cisco’s 5G Converged SDN Transport with the smallest footprint, ever.

●     The only router in the industry with native 25G interfaces in a sub-100G bandwidth form factor allowing cost-effective and seamless backhauling of 5G NR.

●     G.8273.2 Class C Timing complaint.

●     Low power consumption: minimum <40W, typical <70W, maximum 100W.

●     1 RU small form factor routers. Passively cooled (fanless) variants are of 2.5 RU form factor.

●     2.5 RU passively cooled (fanless) routers are suitable for indoor or outdoor cabinets.

●     1RU routers with fans are suitable for indoor or outdoor (Sealed IP65/IP66 cabinet with heat exchanger conforming to GR487 Specs with sufficient cooling) cabinets: I-Temp, conformal-coated form factors conforming to GR-3108 class 2 and ETSI standards.

●     Segment Routing with MPLS (SR-MPLS) and IPv6 data plane (SRv6).

●     Versatile Ethernet interface options: 10/100/1000M, 1/10/25G.

●     Security - Trust Anchor infrastructure, secure boot, image signing, run-time defense.

●     True, secure zero-touch provisioning with the Cisco Crosswork automation suite.

●     Fully compliant to MEF3.0 architecture for wireline networks.*

●     Flexible consumption model.

*Indicates certification post FCS

Cisco NCS 540 Small Density Routers

Cisco NCS 540 Small Density Routers

Cisco NCS 540 Small Density Routers

Cisco NCS 540 Small Density Routers

Cisco NCS 540 Small Density Routers e

Cisco NCS 540 Small Density Routers

Related image, diagram or screenshot

Figure 1.               

Cisco NCS 540 Small Density Routers

Model comparison

Table 1.           NCS 540 Small Density Routers Comparison

Chassis PID

N540X-6Z18G-SYS-A

N540X-6Z18G-SYS-D

N540X-8Z16G-SYS-A

N540X-8Z16G-SYS-D

N540X-4Z14G2Q-A

N540X-4Z14G2Q-D

N540-6Z14S-SYS-D

N540-6Z18G-SYS-A

N540-6Z18G-SYS-D

N540X-6Z6G-SYS

N540-8Z12G-SYS-D

CPU

4-core 2GHz CPU

4-core 2GHz CPU

4-core 2GHz CPU

4-core 2GHz CPU

4-core 2GHz CPU

Quad A 72 SoC 1.8Ghz

4-core 2GHz CPU

Memory

8 GB DRAM

8 GB DRAM

8 GB DRAM

8 GB DRAM

8 GB DRAM

8 GB DRAM

8 GB DRAM

Storage

16 GB eMMC

16 GB eMMC

16 GB eMMC

16 GB eMMC

16 GB eMMC

16 GB eMMC

16 GB eMMC

Interfaces

6x 10/1GE

18x 1GE

8x 10/1GE

4x 1GE SFP

4x 1GE RJ45

8x 1GE SFP or 16x 1GE cSFP

2x 25/10/1GE

4x 10/1GE

10x 1GE SFP

4x 1GE Combo SFP/RJ45

6x 10/1GE

4x 1GE SFP

4x 1GE RJ45

6x 1GE SFP or 12x 1GE cSFP

6x 10/1GE

18x 1GE

6x 10G/1GE

6x 1GE

8x 10/1GE

4x 1GE SFP

4x 1GE RJ45

4x 1GE SFP or 8x 1GE cSFP

Performance

Up to 125 Mpps

Up to 125 Mpps

Up to 125 Mpps

Up to 125 Mpps

Up to 125 Mpps

Up to 125 Mpps

Up to 125 Mpps

Power Supplies

1 + 1 Fixed redundant DC

1 + 1 Fixed redundant AC

1 + 1 Fixed redundant DC

1 + 1 Fixed redundant AC

1 + 1 Fixed redundant DC

1 + 1 Fixed redundant AC

1 + 1 Fixed redundant DC

1 Fixed DC with dual feed

1 Fixed AC

Modular/Redundant (concurrent AC + DC)

1 + 1 Fixed redundant DC

Fans

Fixed redundant fans: 3+1

Fixed redundant fans: 3+1

Fixed redundant fans: 3+1

Fanless

Fixed redundant fans: 2+1

Modular Fan tray /N+1Redundant

Fanless

Airflow

Side to side: right to left

Side to side: right to left

Side to side: right to left

Passively cooled

Front to side**

Front to Back

Passively cooled

Operating Temperature Range

I-Temp:

-40°C to +70°C up to 300 m

-40°C to +65°C up to 1800 m

-40°C to +55°C up to 4000 m

I-Temp:

-40°C to +70°C up to 300 m

-40°C to +65°C up to 1800 m

-40°C to +60°C with CSFP

-40°C to +55°C up to 4000 m

I-Temp:

-40°C to +70°C up to 300 m

-40°C to +65°C up to 1800 m

-40°C to +55°C up to 4000 m

I-Temp:

-20°C to +65°C at 300 m

-20°C to +60°C up to 1800 m

-20°C to +50°C up to 4000 m

C-Temp:

0°C to +55°C at 300 m

0°C to +50°C at 1800 m

+40°C at 4000 m

I-Temp

-40°C to +70°C up to 300 m

-40°C to +65°C up to 1800 m

-40°C to +55°C up to 4000 m

I-Temp:

-20°C to +65°C at 300 m

-20°C to +60°C up to 1800 m

-20°C to +50°C up to 4000 m

Nonoperating (Storage) Temperature

–40°C to +70°C

–40°C to +70°C

–40°C to +70°C

–20°C to +70°C

–5°C to +55°C

–40°C to +70°C

–20°C to +70°C

Operating Humidity Range

5-95% RH, noncondensing

5-95% RH, noncondensing

5-95% RH, noncondensing

5-95% RH, noncondensing

5-95% RH, noncondensing

5-95% RH, noncondensing

5-95% RH, noncondensing

Storage (Relative) Humidity

5-95% at 40°C per NEBS GR-63-Core

5-95% at 40°C per NEBS GR-63-Core

5-95% at 40°C per NEBS GR-63-Core

5-95% at 40°C per NEBS GR-63-Core

5-95% at 40°C per NEBS GR-63-Core

5-95% at 40°C per NEBS GR-63-Core

5-95% at 40°C per NEBS GR-63-Core

Power

Universal AC (90–265V; 50–60 Hz)

Wide range DC (–20V to –72V)

Wide range DC (–40V to –72V)

Universal AC (90–265V; 50–60 Hz)

Wide range DC
(–20V to –72V)

Universal AC (90–264V; 50–60 Hz)

Wide range DC
(–40V to –72V)

Wide range DC (–40V to –72V)

Surge Rating*

4KV common mode

2KV differential mode

4KV common mode

2KV differential mode

4KV common mode

2KV differential mode

4KV common mode

2KV differential mode

1KV common mode

1KV differential mode

AC: 1KV Differential mode, 2KV Common mode

DC: 1KV Differential mode,1KV Common mode

4KV common mode

2KV differential mode

Timing

SyncE, PTP,

Interfaces: 1pps, 10MHz, ToD

Class C

SyncE, PTP,

Interfaces: 1pps, 10MHz, ToD

Class C

Class B on RJ45 1GE

SyncE, PTP,

Interfaces: 1pps, 10MHz, ToD

Class C

Class B on RJ45 1GE

Class B on Ports 14, 15

SyncE, PTP,

Interfaces: 1pps, 10MHz, ToD

Class C

Class B on RJ45 1GE

N/A

SyncE, PTP,

Interfaces: 1pps, 10MHz, ToD

Class C

SyncE, PTP,

Interfaces: 1pps, 10MHz, ToD

Class C

Class B on RJ45 1GE

Physical Specification

Height: 1 RU

Width: 439.5 mm

Depth: 232 mm

Weight: 5.85 kg – AC unit

5.5 kg – DC unit

Height: 1 RU

Width: 445 mm

Depth: 232 mm

Weight: 5.85 kg – AC unit

5.5 kg – DC unit

Height: 1 RU

Width: 445 mm

Depth: 232 mm

Weight: 5.85 kg – AC unit

5.5 kg – DC unit

Height: 2.5 RU

Width: 445 mm

Depth: 384 mm

Weight: 10 kg

Height: 1 RU

Width: 445 mm

Depth: 232 mm

Weight: 3.3 kg – AC unit

3.5 kg – DC unit

Height: 1 RU

Width: 445 mm

Depth: 232 mm

Weight: 6.3 kg

Height: 2.5 RU

Width: 445 mm

Depth: 384 mm

Weight: 10 kg

Conformal Coated

Yes

Yes

Yes

No

No

Yes

No

Mounting Options

19”, 23”, ETSI

19”, 23”, ETSI

19”, 23”, ETSI

19”, 23”

19”, 23”, ETSI

19”, 23”, ETSI

19”, 23”

Management Interfaces

USB console port, USB memory port, RJ45 console

USB console port, USB memory port, RJ45 console

USB console port, USB memory port, RJ45 console

USB console port, USB memory port, RJ45 console

USB console port, USB memory port, RJ45 console

USB console port, USB memory port, RJ45 console

USB console port, USB memory port, RJ45 console

Sensors

Humidity, Altitude

Humidity, Altitude

Humidity, Altitude

No

No

Humidity

No

NEBS GR-3108

Designed to meet Class III when installed in sealed cabinets

Designed to meet Class III when installed in sealed cabinets

Designed to meet Class III when installed in sealed cabinets

Designed to meet Class II

Designed to meet Class I

Designed to meet Class III when installed in sealed cabinets

Designed to meet Class II

*Requires external surge protection devices for installations where higher surge levels are expected. Failure to do so might lead to permanent damage.
**Reach out to your sales if front to back airflow support is needed.

Key software feature support

Table 2.           Key software feature support

Specification

Description

Layer 2

VPWS, VPLS, IRB/BVI v4/v6

Layer 2 forwarding and bridging Bridge Domains (BD)

Ethernet Flow Point (EFP)

IEEE 802.1Q VLANs and Q-in-Q

Ethernet Link Aggregation Group (LAG)

Link Aggregation Control Protocol (LACP) 802.3ad

G.8032

Layer 3

IPv4 and IPv6 unicast routing

Layer 3 interfaces: physical interfaces and subinterfaces

Virtual Routing and Forwarding (VRF)

Open Shortest Path First (OSPFv2, OSPFv3)

Border Gateway Protocol (BGP) v4/v6, LU, PIC, Path Selection, Attributes, TE, Authentication, Security, LS

Multiprotocol Border Gateway Protocol (MP-BGP)

Intermediate System to Intermediate System (ISIS, ISISv6)

Equal-Cost Multipath (ECMP)

Bidirectional Forwarding Detection (BFD) v4/v6, Timers, Routing Protocols, Bundle Interfaces, BFD unnumbered

Virtual Router Redundancy Protocol (VRRP)

Integrated Routing Bridging (IRB) with Bridge Virtual Interface (BVI)

Generic Routing Encapsulation (GRE)

MPLS

Label switching (LER, LSR)

Label Distribution Protocol (LDP)

BGP Labeled Unicast (BGP-LU)

L3 VPN, MPLS Traffic Engineering with RSVP-TE

Point-to-point L2VPN – Static, T-LDP, EVPN-VPWS

Multipoint L2VPN – VPLS, EVPN

L2/L3 EVPN with Anycast IRB

6PE, 6VPE

IP Loop-Free Alternate (LFA) Fast Reroute (FRR)

RSVP-TE Fast Reroute (FRR)

Segment Routing (SR)

Segment Routing with MPLS data plane (SR-MPLS)

Segment Routing with IPv6 data plane (SRv6)

ISIS, OSPF, BGP extensions to segment routing

BGP Egress Peering Engineering (BGP-EPE)

Segment Routing Traffic Engineering (SRTE)

Segment Routing Path Computation Element (SR-PCE)

Topology Independent Loop-Free Alternate (TI-LFA)

Segment Routing On-Demand Next-hop (SR-ODN)

Multicast

IPv4 and IPv6 multicast routing

PIM-SM, PIM-SSM

IGMPv3, MLDv2

mLDP

mVPN

P2MP-TE

Quality of Service (QoS)

Class-based 3-level Hierarchical QoS

Virtual Output Queueing (VOQ)

Policing, Shaping

Multilevel priority queuing

Match, Stats, Classification, Queue management, Remarking

Classification based on L2/L3/L4 fields

Weighted Random Early Detection (WRED)

Deep packet buffer

Timing

SyncE with ESMC

External GNSS receiver

IEEE 1588-2008 PTP T-GM, T-BC, T-TSC

G.8265.1, G.8275.1, G.8275.2

G.8273.2 Class C (Class B on RJ45 1GE)

Security

Control-plane and management plane protection

Local Packet Transport Services (LPTS)

Authentication, Authorization, and Accounting (AAA)

Terminal Access Controller Access-Control System Plus (TACACS+)

Secure Shell (SSH)

Layer 3 ingress and egress ACLs for IPv4 and IPv6

Layer 2 ingress ACLs

Unicast Reverse Path Forwarding (Unicast RPF)

OAM

CDP, LLDP, ICMP, DHCP Relay

IP SLA

MPLS OAM

Ethernet OAM: CFM, Y.1731 DM/SLM

TWAMP

NetFlow

SPAN/ERSPAN

Manageability

CLI, ICMP, EEM, FTP, TFTP, Telnet

SNMP MIB

NETCONF/gRPC (XML, JSON, GPB)

YANG models (native, open: OpenConfig, IETF)

Model/Event-Driven Telemetry

RPM-based SW infrastructure

Zero-Touch Provisioning (ZTP) with iPXE

Supported transceiver modules

Please refer to the Transceiver Module Group (TMG) Compatibility Matrix for the NCS 540 Series supported transceivers.

Regulatory standards compliance

Table 3.           Regulatory standards compliance: Safety and EMC

Specification

Product:

N540X-6Z18G-SYS-D, N540X-6Z18G-SYS-A,

N540X-8Z16G-SYS-D, N540X-8Z16G-SYS-A,

N540X-4Z14G2Q-D, N540X-4Z14G2Q-A

Product:

N540-6Z14S-SYS-D

N540-8Z12G-SYS-D

Product:

N540-6Z18G-SYS-A

N540-6Z18G-SYS-D

Product:

N540X-6Z6G-SYS

Regulatory Compliance

Products comply with CE markings according to directives 2004/108/EC and 2006/95/EC

Products comply with CE markings according to directives 2004/108/EC and 2006/95/EC

Products comply with CE markings according to directives 2004/108/EC and 2006/95/EC

Products comply with CE markings according to directives 2004/108/EC and 2006/95/EC

Network Equipment Building Standards (NEBS)

Designed to meet GR-63-CORE and GR-1089-CORE

Designed to meet GR-63-CORE and GR-1089-CORE

Designed to meet GR-63-CORE and GR-1089-CORE

Designed to meet GR-63-CORE and GR-1089-CORE

Safety

UL 60950-1 Second Edition

CAN/CSA-C22.2 No. 60950-1 Second Edition

EN 60950-1 Second Edition

IEC 60950-1 Second Edition

AS/NZS 60950-1

GB4943

CSA 62368-1

ANSI/UL 62368-1

IEC 62368-1:2014

EN 62368-1:2014+A11:2017

Smart Grid IEEE-1613 (2009+2011), IEEE-1613.1 (2013) and IEC-61850-3 (2013)-N540X-8Z16G-SYS-D

EN50125-3 - N540X-8Z16G-SYS-D

UL 60950-1 Second Edition

CAN/CSA-C22.2 No. 60950-1 Second Edition

EN 60950-1 Second Edition

IEC 60950-1 Second Edition

CSA 62368-1

ANSI/UL 62368-1

IEC 62368-1:2014

EN 62368-1:2014+A11:201760870

Smart Grid IEEE-1613 (2009+2011), IEEE-1613.1 (2013) and IEC-61850-3 (2013) - N540-6Z14S-SYS-D

EN50125-3 - N540-6Z14S-SYS-D

UL 60950-1 Second Edition

CAN/CSA-C22.2 No. 60950-1 Second Edition

EN 60950-1 Second Edition

IEC 60950-1 Second Edition

CSA 62368-1: 2019

ANSI/UL 62368-1: 3

d Edition

IEC 62368-1:2020

EN 62368-1:2020

UL 60950-1 Second Edition

CAN/CSA-C22.2 No. 60950-1 Second Edition

EN 60950-1 Second Edition

IEC 60950-1 Second Edition

CSA 62368-1: 2019

ANSI/UL 62368-1: 3rd Edition

IEC 62368-1:2020

EN 62368-1:2020

ANSI / UL 60950-1 
CAN/CSA C22.2 No. 60950-1 

ANSI / UL 62368-1 
CAN/CSA C22.2 No. 62368-1 
EN / IEC 62368-1

EMC Standards

EN55032:2015

EN61000-3-2:2014

ICES-003:2016:Iss:6

EN55032:2012

47 CFR Part 15:2016

KN61000-3-3:2014

CISPR32:2015:Ed:2

CNS13438:2006

KN32:2015

EN300 386:2012:V1.6.1

KN61000-3-2:2014

VCCI-CISPR 32:2016

EN61000-3-3:2013

TEC/SD/DD/EMC-221/05/OCT-16

EN50121-4:2016

EN50121-4:2016:A1:2019

IEC62236-4:2018:Ed:3.0

EN55032:2015

EN61000-3-2:2014

ICES-003:2016:Iss:6

EN55032:2012

47 CFR Part 15:2016

KS C 9610-3-3:2020

CISPR32:2015:Ed:2

CNS13438:2006

KS C 9832

EN300 386:2012:V1.6.1

KS C 9610-3-2:2020

VCCI-CISPR 32:2016

EN61000-3-3:2013

TEC/SD/DD/EMC-221/05/OCT-16

EN50121-4:2016

EN50121-4:2016:A1:2019

EN55032:2015

EN61000-3-2:2014

ICES-003:2016:Iss:6

EN55032:2012

47 CFR Part 15:2016

KS C 9610-3-3:2020

CISPR32:2015:Ed:2

CNS13438:2006

KS C 9832

EN300 386:2012:V1.6.1

KS C 9610-3-2:2020

VCCI-CISPR 32:2016

EN61000-3-3:2013

TEC/SD/DD/EMC-221/05/OCT-16

EN50121-4:2016

EN50121-4:2016:A1:2019

EN55032:2015

EN61000-3-2:2014

ICES-003:2016:Iss:6

EN55032:2012

47 CFR Part 15:2016

KS C 9610-3-3:2020

CISPR32:2015:Ed:2

CNS13438:2006

KS C 9832

EN300 386:2012:V1.6.1

KS C 9610-3-2:2020

VCCI-CISPR 32:2016

EN61000-3-3:2013

TEC/SD/DD/EMC-221/05/OCT-16

EN50121-4:2016

EN50121-4:2016:A1:2019

EMC Immunity

IEC/EN61000-4-2

IEC/EN61000-4-3

IEC/EN61000-4-4

IEC/EN61000-4-5

IEC/EN61000-4-6

IEC/EN61000-4-11

CISPR24:2010+A1:2015

CISPR35:2016:Ed:1

EN IEC61000-6-1:2019

EN300 386:2012:V1.6.1

EN55024:2010

EN55024:2010:A1

EN55035:2017

EN61000-6-1:2007

EN61000-6-2:2019

IEC61000-6-1:2016:Ed:3

IEC61000-6-2:2016:Ed:3

KN35:2015

EN50121-4:2016

EN50121-4:2016:A1:2019

IEC62236-4:2018:Ed:3.0

IEC61000-4-5 (4kV/CM and 2kV/DM on DC input)

IEC/EN61000-4-2

IEC/EN61000-4-3

IEC/EN61000-4-4

IEC/EN61000-4-5

IEC/EN61000-4-6

IEC/EN61000-4-11

CISPR24:2010+A1:2015

CISPR35:2016:Ed:1

EN IEC61000-6-1:2019

EN300 386:2012:V1.6.1

EN55024:2010

EN55024:2010:A1

EN55035:2017

EN61000-6-1:2007

EN61000-6-2:2019

IEC61000-6-1:2016:Ed:3

IEC61000-6-2:2016:Ed:3

KS C 9835

IEC 61850-3 - N540-6Z14S-SYS-D

IEC/EN61000-4-2

IEC/EN61000-4-3

IEC/EN61000-4-4

IEC/EN61000-4-5

IEC/EN61000-4-6

IEC/EN61000-4-11

CISPR24:2010+A1:2015

CISPR35:2016:Ed:1

EN IEC61000-6-1:2019

EN300 386:2012:V1.6.1

EN55024:2010

EN55024:2010:A1

EN55035:2017

EN61000-6-1:2007

EN61000-6-2:2019

IEC61000-6-1:2016:Ed:3

IEC61000-6-2:2016:Ed:3

KS C 9835

IEC/EN61000-4-2

IEC/EN61000-4-3

IEC/EN61000-4-4

IEC/EN61000-4-5

IEC/EN61000-4-6

IEC/EN61000-4-11

CISPR24:2010+A1:2015

CISPR35:2016:Ed:1

EN IEC61000-6-1:2019

EN300 386:2012:V1.6.1

EN55024:2010

EN55024:2010:A1

EN55035:2017

EN61000-6-1:2007

EN61000-6-2:2019

IEC61000-6-1:2016:Ed:3

IEC61000-6-2:2016:Ed:3

KS C 9835

ETSI

ETS/EN 300 119 Part 4

ETS/EN 300 019 - Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2

ETS/EN 300 753

ETS/EN 300 119 Part 4

ETS/EN 300 019 - Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2

ETS/EN 300 753

ETS/EN 300 119 Part 4

ETS/EN 300 019 - Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2

ETS/EN 300 753

ETS/EN 300 119 Part 4

ETS/EN 300 019 - Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2

ETS/EN 300 753

RoHS

The product is RoHS-6 compliant with exceptions for leaded-Ball Grid-Array (BGA) balls and lead press-fit connectors.

The product is RoHS-6 compliant with exceptions for leaded-Ball Grid-Array (BGA) balls and lead press-fit connectors.

The product is RoHS-6 compliant with exceptions for leaded-Ball Grid-Array (BGA) balls and lead press-fit connectors.

The product is RoHS-6 compliant with exceptions for leaded-Ball Grid-Array (BGA) balls and lead press-fit connectors.

Ordering information

Table 4.           Ordering information

Router PID

N540X-6Z18G-SYS-A

N540X-6Z18G-SYS-D

N540X-8Z16G-SYS-A

N540X-8Z16G-SYS-D

N540X-4Z14G2Q-A

N540X-4Z14G2Q-D

N540-6Z14S-SYS-D

N540-6Z18G-SYS-A

N540-6Z18G-SYS-D

N540X-6Z6G-SYS

N540-8Z12G-SYS-D

Description

NCS540 18x1G SFP + 6x1/10G SFP+ Dual-AC iTEMP Conformal-Coated Chassis

NCS540 18x1G SFP + 6x1/10G SFP+ Dual-DC iTEMP Conformal-Coated Chassis

N540 12/20(CSFP) x1G + 4x1GCu + 8x1/10G Dual-AC iTEMP Conformal-Coated Chassis

N540 12/20(CSFP) x1G + 4x1GCu + 8x1/10G Dual-DC iTEMP Conformal-Coated Chassis

NCS540 14x1G + 4x1/10G + 2x10/25G Dual-AC iTEMP Conformal-Coated Chassis

NCS540 14x1G + 4x1/10G + 2x10/25G Dual-DC iTEMP Conformal-Coated Chassis

N540 10/6(CSFP) x1G + 4x1GCu + 6x1/10G Dual-DC iTEMP

NCS540 18x1G SFP + 6x1/10G SFP+ AC cTEMP Chassis

NCS540 18x1G SFP + 6x1/10G SFP+ DC cTEMP Chassis

NCS540 6x1G SFP + 6x1/10G SFP+ Dual-AC /DC iTEMP Conformal-Coated Chassis

N540 8/4(CSFP) 4x1G + 4x1GCu + 8x1/10G Dual-DC iTEMP

Power Supplies

Fans Accessories

 

 

 

 

 

Power Supply:

N540-PWR400-A

N540-PWR400-D

Fan Tray

N540X-6Z6G-FT

 

Rackmount for AC Variant

N540-RCKMT-19-ACA

N540-RCKMT-23-ACA

N540-RKMT-ETSI-ACA

N540-RCKMT-19-ACA

N540-RCKMT-23-ACA

N540-RKMT-ETSI-ACA

N540-RCKMT-19-ACA

N540-RCKMT-23-ACA

N540-RKMT-ETSI-ACA

Not Applicable

N540-RCKMT-19-ACA

N540-RCKMT-23-ACA

N540-RKMT-ETSI-ACA

N540-RCKMT-PLA

(Rackmount + adapters for 23" and ETSI)

Not Applicable

Rackmount for DC Variant

N540-RCKMT-19-ACD

N540-RCKMT-23-ACD

N540-RKMT-ETSI-ACD

N540-RCKMT-19-ACD

N540-RCKMT-23-ACD

N540-RKMT-ETSI-ACD

N540-RCKMT-19-ACD

N540-RCKMT-23-ACD

N540-RKMT-ETSI-ACD

N540-RCKMT-19-MRK

N540-RCKMT-23-MRK

N540-RCKMT-19-ACD

N540-RCKMT-23-ACD

N540-RKMT-ETSI-ACD

N540-RCKMT-19-ACD

N540-RCKMT-23-ACD

N540-RKMT-ETSI-ACD

N540-RCKMT-19-MRK

N540-RCKMT-23-MRK

Cable Bracket

N540-CBL-BRKT-AC

N540-CBL-BRKT-AC

N540-CBL-BRKT-AC

 

N540-CBL-BRKT-AC

N540-CBL-BRKT-AC

A920-CBL-GUIDE-PC

F2B Plenum Accessories

Not Applicable

Not Applicable

Not Applicable

Not Applicable

N540-6Z18G-PL-E

N540-6Z18G-PL-23

N540-CBL-BRKT-FN

Not Applicable

N540-PKG-CVR

FCS Software

IOS XR 7.3.1

IOS XR 7.3.1

IOS XR 7.4.1

IOS XR 7.5.2

IOS XR 7.8.1

IOS XR 25.4.1

IOS XR 26.2.1

Table 5.           Ordering information for software licenses available on NCS 540 portfolio. Learn more.

Product ID (PID)

Description

ESS-AC-10G-RTU-1

Access Essentials SW Right-to-Use v1.0 per 10G

ADV-AC-10G-RTU-1

Access Advantage w/o Essentials SW RTU v1.0 10G

ADN-AC-10G-RTU-1

Access Advantage w/ Essentials SW RTU v1.0 10G

ESS-ADN-AC-10G-RT

Access Essentials to Advantage Upgrade RTU per 10G

ESS-AC-10G-SIA-3

Access Essentials SIA 10G 3-5 year term

ESS-AC-10G-SIA-5

Access Essentials SIA 10G 5-10 year term

ADV-AC-10G-SIA-3

Access Advantage w/o Essentials SIA 10G 3-5 year term

ADV-AC-10G-SIA-5

Access Advantage w/o Essentials SIA 10G 5-10 year term

ADN-AC-10G-SIA-3

Access Advantage w/ Essentials SIA 10G 3-5 year term

ADN-AC-10G-SIA-5

Access Advantage w/ Essentials SIA 10G 5-10 year term

ESS-ADN-AC-10G-S3

Access Essentials to Advantage Upgrade SIA 10G 3-5 yrs

ESS-ADN-AC-10G-S5

Access Essentials to Advantage Upgrade SIA 10G 5-10 yrs

N540-24Z8Q2C-FC-SW

NCS 540 Series additional Software Licenses (RTU, SIA)

Table 6.           Ordering information for power cables supported

Part number

Description

CAB-AC-SA

Power Cord - South Africa, 16/10A, 250V, 1830mm, -40C to +85C

CAB-AC-ARG

Power Cord - Argentina, 10A, 250V, 2500mm, -40C to +85C

CAB-AC-ISR

Power Cord - Israel, 16/10A, 250V, 2500mm, -40C to +85C

CAB-AC-TAI

Power Cord - Taiwan, 15/10A, 125V, 2500mm, -40C to +85C

CAB-AC-CHI

Power Cord - China, 10A, 250V, 2500mm, -40C to +85C

CAB-AC-KOR

Power Cord - Korea, 16/10A, 125V, 2500mm, -40C to +85C

CAB-AC-EUR

Power Cord - Europe, 16/10A, 250V, 2500mm, -40C to +85C

CAB-AC-ITL

Power Cord - Italy, 10A, 250V, 2500mm, -40C to +85C

CAB-AC-UK

Power Cord - UK, 13/10A, 250V, 2500mm, -40C to +85C

CAB-AC-AUS

Power Cord - Australia, 10A, 250V, 2500mm, -40C to +85C

CAB-AC-US

Power Cord - US, 15A, 125V, 2500mm, -40C to +85C

CAB-AC-BRA

Power Cord - Brazil, 10A, 250V, 2500mm, -40C to +85C

CAB-AC-IND

Power Cord - India, 16/10A, 250V, 2500mm, -40C to +85C

CAB-AC-SUI

Power Cord - Swiss, 10A, 250V, 2500mm, -40C to +85C

Be the first to write a review for this product.

Write a review

Please login or register to review