Cisco PWR-IE65W-PC-AC Industrial Power Supply
- Global Price List Information (GPL)
-
Model: PWR-IE65W-PC-AC-RF
-
Description:
-
Price: USDLast Update:
- End-of-Sale and End-of-Life Information (EOL/EOS)
- Release Date:
- End-of-Sale Date:
- End-of-Support Date:
- Description
- Datasheet
- Documents
- Videos
- Training
- Softwares
- Accessories & Spare Parts
- Global Price List
- Reviews (0)
Cisco provides robust industrial power solutions designed to support critical infrastructure and reliable networking in harsh operational environments. These specialized power supplies ensure seamless uptime for industrial automation, transportation, and energy applications where standard commercial hardware fails.
Engineered to meet rigorous industrial standards, Cisco’s power systems offer resilient performance under extreme temperature fluctuations and electrical disturbances. They integrate smoothly with existing enterprise management frameworks to simplify deployment and reduce operational downtime.
Product overview
The portfolio highlights the Cisco Industrial DIN-Rail Power Supplies, including models such as the 120W, 240W, and 480W variants. These units are built to deliver continuous, regulated DC power to industrial switches, controllers, and edge devices.
Each power supply unit features a compact, ruggedized DIN-rail mountable enclosure designed for space-constrained industrial control cabinets. They support wide input voltage ranges and deliver high energy efficiency while maintaining stable output performance across diverse operational loads.
Features and benefits
- High reliability and long operational life under harsh industrial conditions, minimizing maintenance and replacement costs.
- Wide operating temperature range, making them suitable for deployment in unconditioned outdoor cabinets or heavy manufacturing floors.
- Overload, short-circuit, and overvoltage protection mechanisms to safeguard connected networking equipment from electrical hazards.
- High power conversion efficiency that reduces energy consumption and thermal dissipation within control enclosures.
- Compact DIN-rail mounting design that optimizes cabinet space and enables quick, tool-free installation.
- Seamless compatibility and electrical matching with Cisco Industrial Ethernet switches and IoT devices.
The Cisco portfolio of industrial DIN-rail power supplies offers a wide range of options to power industrial Ethernet switches, industrial routers, and industrial computing products.
Product overview
The Cisco industrial DIN-rail power supplies offer a variety of rugged, reliable, and compact AC and DC power supply options to power Cisco’s industrial Ethernet switches, industrial routers (including industrial gateways), and industrial computing products. Some key features include:
● Power supply options from 50W to 480W
● Operating temperatures ranging between -40°C and +85°C
● DIN-rail mountable
● Enables of high-capacity Power over Ethernet (PoE)
● Hardwired and IEC plug-in models available
● Conformal coating options
Table 1 shows a list of all DIN-rail power supplies.
Table 1. DIN-rail power supplies part numbers and descriptions
| Part number |
Product image |
Product description |
PoE / PoE+ /4PPoE support |
Input Connection Type |
| PWR-IE50W-AC-L= |
|
50W AC to DC power supply |
No |
Hardwired |
| PWR-IE50W-AC= |
|
50W AC to DC or High DC to DC power supply |
No |
Hardwired |
| PWR-IE50W-AC-IEC= |
|
50W AC to DC power supply with IEC connector (IEC 60320 C14) |
No |
Plug-in |
| PWR-IE65W-PC-AC= |
|
65W AC to DC or High DC to DC power supply |
Yes |
Hardwired |
| PWR-IE65W-PC-DC= |
|
65W Low DC to DC power supply |
Yes |
Hardwired |
| PWR-IE170W-PC-AC= |
|
170W AC to DC or High DC to DC power supply |
Yes |
Hardwired |
| PWR-IE170W-PC-DC= |
|
170W Low DC to DC power supply |
Yes |
Hardwired |
| PWR-IE240W-PCAC-L=1 |
|
240W AC to DC power supply |
Yes |
Hardwired |
| PWR-IE240W-AC-IEC=1,2 |
|
240W AC to DC power supply with IEC connector (IEC 60320 C16) |
Yes |
Plug-in |
| PWR-IE400W-AC-IEC=1,2 |
|
400W AC to DC power supply with IEC connector (IEC 60320 C16) |
Yes |
Plug-in |
| PWR-IE480W-PCAC-L =1 |
|
480W AC to DC power supply |
Yes |
Hardwired |
Product specifications
Table 2 lists the input specification for Cisco industrial power supplies. Table 3 lists the output specifications.
Table 2. Input specifications
| Product ID |
Rated nominal input operating range |
Supported input voltage operating range |
Typical efficiency |
Inrush current at 25C ambient |
Remarks |
| PWR-IE50W-AC-L= |
AC 100-240V/1.2A, 50-60Hz |
AC 90-264V |
88% |
< 35A @ 115VAC and 70A @ 230VAC |
Not approved for hazardous location installations |
| PWR-IE50W-AC= |
AC 100-240V/1.25A, 50-60Hz or DC 125-250V/1.25A |
AC 90-264V or DC 106-300V |
80% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations |
| PWR-IE50W-AC-IEC= |
AC 100-240V/1.25A, 50-60Hz |
AC 90-264V |
80% |
< 35A @ 115VAC and 70A @ 230VAC |
Not approved for hazardous location installations |
| PWR-IE65W-PC-AC= |
AC 100-240V/1.4A, 50-60Hz or DC 125-250V/1.0A |
AC 90-264V or DC 106-300V |
85% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations CSA certified |
| PWR-IE65W-PC-DC= |
DC 24-48VDC/4.5A |
DC 18-60V |
92% |
4A@24VDC |
Approved for Class 1, Div 2/Zone 2 installations |
| PWR-IE170W-PC-AC= |
AC 100-240V/2.3A, 50-60Hz or DC 125-250V/2.1A |
AC 90-264V or DC 106-300V |
88% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations CSA certified |
| PWR-IE170W-PC-DC= |
DC 12-54V/23A |
DC 10.8-60V |
88% |
17.3A @ 12VDC |
Approved for Class 1, Div 2/Zone 2 installations |
| PWR-IE240W-PCAC-L= |
AC 100-240V/3.5A, 50-60Hz |
AC 90-264V |
91% |
< 35A @ 115VAC and 230VAC |
Not approved for hazardous location installations |
| PWR-IE240W-AC-IEC= |
AC 100-240V/3.1A, 50-60Hz |
AC 90-264V |
90% |
< 45A @ 115VAC and 230VAC |
Not approved for hazardous location installations |
| PWR-IE400W-AC-IEC= |
AC 100-240V/5A, 50-60Hz |
AC 90-264V |
91% |
< 35A @ 115VAC and 230VAC |
Not approved for hazardous location installations |
| PWR-IE480W-PCAC-L= |
AC 100-240V/6A, 50-60Hz |
AC 90-264V |
92% |
< 35A @ 115VAC and 230VAC |
Not approved for hazardous location installations |
Table 3 lists the output specifications for Cisco industrial power supplies.
Table 3. Output specifications
| Product ID |
Nominal output voltage / adjustment range |
Max output power |
Holdup time at 100% load |
Protections |
| PWR-IE50W-AC-L= |
24VDC / 24-28VDC, 2.1A |
50W |
20ms |
Over temperature protection Short circuit protection |
| PWR-IE50W-AC= |
24VDC, 2.1A |
50W |
20ms |
|
| PWR-IE50W-AC-IEC= |
24VDC, 2.1A |
50W |
20ms |
|
| PWR-IE65W-PC-AC= |
54VDC, 1.2A |
65W |
10ms |
|
| PWR-IE65W-PC-DC= |
54VDC, 1.2A |
65W |
||
| PWR-IE170W-PC-AC= |
54VDC, 3.2A |
170W |
20ms |
|
| PWR-IE170W-PC-DC= |
54VDC, 3.2A |
170W |
9ms (@10.8VDC) to 25.9ms (@ 60VDC) |
|
| PWR-IE240W-PCAC-L= |
54VDC / 48-56VDC, 4.5A |
240W |
20ms |
|
| PWR-IE240W-AC-IEC= |
55VDC, 4.4A |
240W |
20ms |
|
| PWR-IE400W-AC-IEC= |
55VDC, 7.3A |
400W |
20ms |
|
| PWR-IE480W-PCAC-L= |
54VDC / 48-56VDC, 8.9A |
480W |
20ms |
Table 4 lists the environmental specifications for Cisco industrial power supplies.
Table 4. Environmental specifications
| Product ID |
IP rating |
Operating temperature |
Storage temperature |
Power derating |
Operating humidity |
| PWR-IE50W-AC-L= |
IP20 |
-20°C to +70°C |
-40°C to +85°C |
> 55°C de-rate power by 3.33%/°C < -10°C de-rate power by 2%/°C |
5 to 95% RH (non-condensing) |
| PWR-IE50W-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
| PWR-IE50W-AC-IEC= |
IP20 |
-20°C to +70°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
| PWR-IE65W-PC-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
| PWR-IE65W-PC-DC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
| PWR-IE170W-PC-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
| PWR-IE170W-PC-DC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
| PWR-IE240W-PCAC-L= |
IP20 |
-40°C to +80°C |
-40°C to +85°C |
Vertical mounting: > 50°C de-rate power by 2.5%/°C Horizontal mounting: > 40°C de-rate power by 2.5%/°C |
5 to 95% RH (non-condensing) |
| PWR-IE240W-AC-IEC=1,2 |
IP20 |
-40°C to +85°C |
-40°C to +85°C |
Vertical mounting: > 50°C to 85°C de-rate power by 2.5%/°C |
5 to 95% RH (non-condensing) |
| PWR-IE400W-AC-IEC=1,2 |
IP20 |
-40°C to +85°C |
-40°C to +85°C |
Vertical mounting: > 50°C to 85°C de-rate power by 2.5%/°C |
5 to 95% RH (non-condensing) |
| PWR-IE480W-PCAC-L= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
Vertical mounting: > 50°C de-rate power by 2.5%/°C > 70°C de-rate power by 5%/°C |
5 to 95% RH (non-condensing) |
Table 5 lists the Safety standards/EMC for Cisco industrial power supplies.
Table 5. Safety standards / EMC
| Product ID |
Electric safety |
EMC/ Industry standards |
| PWR-IE50W-AC-L= |
CE (EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC) UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 CB scheme to IEC 60950-1, LPS NEC Class 2 |
EN 61000-3-2 Class A, EN 61000-3-3 EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61204-3, EN 55035 (EN 61000-4-2,3,4,5,6,8,11) CISPR 32, EN 55032, CISPR 11, EN 55011, FCC 47 CFR part 15B |
| PWR-IE50W-AC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN61131-2: 2007 EN62368-1: 2014 + A11: 2017 IEC60950-1: 2005+A1: 2009+A2: 2013 IEC62368-1: 2014 EN 60079-0:2012 + A11:2013, EN 60079-15:2010 CE |
EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11 IEC61000-4-11, IEC61000-4-12, IEC61000-4-16 CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B |
| PWR-IE50W-AC-IEC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN62368-1: 2014 + A11: 2017 CE |
EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11 IEC61000-4-11, IEC61000-4-12, IEC61000-4-16 CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B |
| PWR-IE65W-PC-AC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN61131-2: 2007 EN62368-1: 2014 + A11: 2017 IEC60950-1: 2005+A1: 2009+A2: 2013 IEC62368-1: 2014 UL 508 Class 1, Div 2/ Zone 2 Hazardous location CE UL60950-1 and CSA60950-1 certified |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12, EN61131-2: 2007 CISPR 32, EN 55032, CISPR35, EN55035 FCC47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
| PWR-IE65W-PC-DC= |
EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 508 Class 1, Div2/ Zone 2 Hazardous Location CCC CE |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
| PWR-IE170W-PC-AC= |
IEC60950-1: 2005+A1: 2009+A2: 2013 EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, KCC mark, BSMI mark, CCC, CB Scheme, Class 1, Div2/ Zone 2 Hazardous Location CE UL60950-1and CSA60950-1 certified |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12 CISPR 32, EN 55032, CISPR35, EN55035 47 CFR FCC part 15B EN61131-2: 2007 IEC 61850-3, IEEE 1613 EN50121-4:2016 |
| PWR-IE170W-PC-DC= |
EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 508 Class 1, Div 2/Zone 2 Hazardous location CE |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
| PWR-IE240W-PCAC-L= |
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) |
EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12) CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR Part15B |
| PWR-IE240W-AC-IEC= |
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) UL 62368-1 (File No. E191395) CSA C22.2 No. 107.1-01 (File No. 181564) |
EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12) CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR Part15B |
| PWR-IE400W-AC-IEC= |
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) UL 62368-1 (File No. E191395) CSA C22.2 No. 107.1-01 (File No. 181564) |
EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12) CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR Part 15B |
| PWR-IE480W-PCAC-L= |
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) |
EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12) CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR Part 15B |
Table 6 lists the Mechanical and Reliability data for Cisco industrial power supplies.
Table 6. Mechanical and Reliability data
| Product ID |
Dimensions (W x H x D) |
Unit weight |
MTBF (Telcordia SR-332) |
| PWR-IE50W-AC-L= |
30 mm x 75 mm x 89.5 mm 1.18 in x 2.95 in x 3.52 in |
0.39 lb (0.18 kg) |
2,255,613 hours |
| PWR-IE50W-AC= |
51 mm x 118 mm x 148 mm 2 in x 4.64 in x 5.82 in |
1.41 lb (0.64 kg) |
1,662,359 hours |
| PWR-IE50W-AC-IEC= |
51 mm x 118 mm x 148 mm 2 in x 4.64 in x 5.82 in |
1.43 lb (0.65 kg) |
1,662,359 hours |
| PWR-IE65W-PC-AC= |
66 mm x 148 mm x 118 mm 2.5 in x 5.82 in x 4.64 in |
2.64 lb (1.2 kg) |
2,488,401 hours |
| PWR-IE65W-PC-DC= |
66 mm x 150 mm x 117 mm 2.59 in x 5.90 in x 4.60 in |
2.60 lb (1.18 kg) |
4,802,673 hours |
| PWR-IE170W-PC-AC= |
96 mm x 150 mm x 146 mm 3.77 in x 5.90 in x 5.74 in |
3.88 lb (1.76 kg) |
2,384,975 hours |
| PWR-IE170W-PC-DC= |
114 mm x 150 mm x 146 mm 4.48 in x 5.90 in x 5.74 in |
3.68 lb (1.67 kg) |
2,164,641 hours |
| PWR-IE240W-PCAC-L= |
85 mm x 121 mm x 124.1 mm 3.34 in x 4.76 in x 4.88 in |
2.11 lb (0.96 kg) |
1,579,900 hours |
| PWR-IE240W-AC-IEC= |
85 mm x 120 mm x 127 mm 3.34 in x 4.72 in x 5.0 in |
2.25 lb (1.02 kg) |
2,084,151 hours |
| PWR-IE400W-AC-IEC= |
144 mm x 120 mm x 126 mm 5.56 in x 4.72 in x 5.0 in |
3.10 lb (1.41 kg) |
1,411,751 hours |
| PWR-IE480W-PCAC-L= |
144 mm x 121 mm x 118.6 mm 5.66 in x 4.76 in x 4.66 in |
3.02 lb (1.37 kg) |
1,058,750 hours |
Ordering information
Table 7 provides ordering information for Cisco industrial power supplies.
Table 7. Ordering information
| Part # |
Product description |
| PWR-IE50W-AC-L= |
50W AC to DC power supply |
| PWR-IE50W-AC= |
50W AC to DC power supply |
| PWR-IE50W-AC-IEC= |
50W AC to DC power supply with IEC connector (IEC 60320 C14) |
| PWR-IE65W-PC-AC= |
65W AC to DC power supply |
| PWR-IE65W-PC-DC= |
65W DC to DC power supply |
| PWR-IE170W-PC-AC= |
170W AC to DC power supply |
| PWR-IE170W-PC-DC= |
170W DC to DC power supply |
| PWR-IE240W-PCAC-L= |
240W AC to DC power supply |
| PWR-IE240W-AC-IEC= |
240W AC to DC power supply with IEC connector (IEC 60320 C16) |
| PWR-IE400W-AC-IEC= |
400W AC to DC power supply with IEC connector (IEC 60320 C16) |
| PWR-IE480W-PCAC-L= |
480W AC to DC power supply |
| CAB-DC-381=1 |
DC Power Cable for PWR-IE240W-AC-IEC= with 3.81mm connector (1M) for IE3100 Series |
| CAB-DC-500=2 |
DC Power Cable for PWR-IE240W-AC-IEC= with 5.00mm connector (1M) for IE3200, IE3300, IE3400, IE3500 Series |
| Model | PWR-IE65W-PC-AC-RF |